Search results for "Photon beam"
showing 10 items of 21 documents
Regge phenomenology in π0 and η photoproduction
2017
The $\ensuremath{\gamma}N\ensuremath{\rightarrow}{\ensuremath{\pi}}^{0}N$ and $\ensuremath{\gamma}N\ensuremath{\rightarrow}\ensuremath{\eta}N$ reactions at photon beam energies above 4 GeV are investigated within Regge models. The models include $t$-channel exchanges of vector ($\ensuremath{\rho}$ and $\ensuremath{\omega}$) and axial-vector (${b}_{1}$ and ${h}_{1}$) mesons. Moreover, Regge cuts of $\ensuremath{\rho}\mathbb{P},\phantom{\rule{0.28em}{0ex}}\ensuremath{\rho}{f}_{2},\phantom{\rule{0.28em}{0ex}}\ensuremath{\omega}\mathbb{P}$, and $\ensuremath{\omega}{f}_{2}$ are investigated. A good description of differential cross sections and polarization observables at photon beam energies fr…
A new measurement of the neutron detection efficiency for the NaI Crystal Ball detector
2015
We report on a measurement of the neutron detection efficiency in NaI crystals in the Crystal Ball detector obtained from a study of single π0 photoproduction on deuterium using the tagged photon beam at the Mainz Microtron. The results were obtained up to a neutron energy of 400 MeV . They are compared to previous measurements made more than 15 years ago at the pion beam at the BNL AGS.
2021
Purpose First, this experimental study aims at comparing out-of-field doses delivered by three radiotherapy techniques (3DCRT, VMAT (two different accelerators), and tomotherapy) for a pediatric renal treatment. Secondly, the accuracy of treatment planning systems (TPS) for out-of-field calculation is evaluated. Methods EBT3 films were positioned in pediatric phantoms (5 and 10 yr old). They were irradiated according to four plans: 3DCRT (Clinac 2100CS, Varian), VMAT (Clinac 2100CS and Halcyon, Varian), and tomotherapy for a same target volume. 3D dose determination was performed with an in-house Matlab tool using linear interpolation of film measurements. 1D and 3D comparisons were made be…
Determination of consensus kQ values for megavoltage photon beams for the update of IAEA TRS-398
2020
The IAEA is currently coordinating a multi-year project to update the TRS-398 Code of Practice for the dosimetry of external beam radiotherapy based on standards of absorbed dose to water. One major aspect of the project is the determination of new beam quality correction factors, kQ, for megavoltage photon beams consistent with developments in radiotherapy dosimetry and technology since the publication of TRS-398 in 2000. Specifically, all values must be based on, or consistent with, the key data of ICRU Report 90. Data sets obtained from Monte Carlo (MC) calculations by advanced users and measurements at primary standards laboratories have been compiled for 23 cylindrical ionization chamb…
Photoreactions with tensor-polarized deuterium target at VEPP–3
2011
We give an overview of the activity in studying photoprocesses on a tensor-polarized deuterium target, which is carried out at the VEPP–3 electron storage ring. Recent experimental results on tensor asymmetries in two-body deuteron photodisintegration at the photon energy up to 500 MeV, and in coherent pion photoproduction on deuteron are presented. Plans to upgrade the facility and future experiments are discussed. Further progress is connected with the installation of a tagging system for almost-real photons. This would allow us to extend the measurements of polarization observables in photonuclear reactions on deuteron up to a photon energy of 1.5 GeV and permit to perform double polariz…
THE BARYON RESONANCE PROGRAM AT MAMI
2010
The Mainz Microtron MAMI is an ideal facility to study the hadron structure with the electromagnetic probe. With the fourth accelerator stage (MAMI-C) which went into operation in 2007 high-intensity polarized electron and photon beams with energies up to 1.5 GeV are delivered to the experiments. Polarized targets and recoil polarimeters in combination with dedicated detectors are available for precision experiments in hadron physics. In this article, an overview over selected recent results on the study of low-lying baryon resonances and future perspectives will be given.
Total photoabsorption cross sections forH1,H2, andHe3from 200 to 800 MeV
1996
The total photoabsorption cross sections for $^{1}\mathrm{H}$, $^{2}\mathrm{H}$, and $^{3}\mathrm{He}$ have been measured for incident photon energies ranging from 200 to 800 MeV. The $^{3}\mathrm{He}$ data are the first for this nucleus. By using the large acceptance detector DAPHNE in conjunction with the tagged photon beam facility of the MAMI accelerator in Mainz, cross sections of high precision have been obtained. The results show clearly the changes in the nucleon resonances in going from $^{1}\mathrm{H}$ to $^{3}\mathrm{He}$. In particular, for the ${\mathit{D}}_{13}$ region the behavior for $^{3}\mathrm{He}$ is intermediate between that for $^{1}\mathrm{H}$, $^{2}\mathrm{H}$, and h…
Total cross section measurement for the three double pion photoproduction channels on the proton
1995
Abstract The total cross sections for the three γp → Nππ reactions have been measured for photon energies from 400 to 800 MeV. The γ p → p π 0 π 0 and γ p → n π + π 0 cross sections have never been measured before while the γ p → p π + π − results are much improved compared to earlier data. These measurements were performed with the large acceptance hadronic detector DAPHNE, at the tagged photon beam facility of the MAMI microtron in Mainz.
A compact 4He cryotarget
1998
Abstract A thin walled cell of 8 cm length and 3 cm diameter has been constructed for liquid 4 He to be used as a target in a tagged photon beam. The target and the housing have been optimised to allow for detection of charged particles emitted on both sides of the beam. A reservoir of 3 l liquid He and good thermal insulation permitted refilling cycles of 12 h.
Discrimination of LINAC photon and sunlight contributions in watch glass analyzed by means of thermoluminescence
2012
Abstract The research described in this paper shows how to extract from the glow curves of watch glasses exposed to LINAC photons and sunlight a contribution sensitive to LINAC photons dose. As first step, the dependence of the TL signal due to sunlight on the exposure duration was studied and a signal saturation was observed after about 20 weeks. The comparison of TL signals due to solar light and to LINAC photons highlights a partial overlap of the two signals. Here, two different analysis procedures of glow curves (general order kinetics deconvolution and principal components analysis) are reported to point out components which depend differently on LINAC photon radiation dose. For both …